Hefei Shinhoo New Energy Co.,ltd.
We are committed to providing customers with professional thermal management system solutions for new energy vehicles.
Hefei Shinhoo New Energy Co., Ltd. (Shinhoo), a wholly-owned subsidiary of Zhejiang Dayuan Pump Co., Ltd. (Stock Code: 603757), operates as a technology-driven enterprise specializing in thermal management solutions for the new energy sector. Headquartered in Hefei, China, we excel in the R&D, production, and global distribution of advanced liquid cooling systems.

<table style="border-collapse:collapse; width:auto"> <colgroup> <col style="width:207.00pt" width="276" /> <col style="width:163.50pt" width="218" /> </colgroup> <tbody> <tr> <td x:str=""><strong>Rated flow head</strong></td> <td x:str="">16L/min@7m</td> </tr> <tr> <td x:str=""><strong>Power</strong></td> <td x:str="">60W</td> </tr> <tr> <td x:str=""><strong>Voltage range</strong></td> <td x:str="">8 ~ 16VDC</td> </tr> <tr> <td x:str=""><strong>Maximum flow</strong></td> <td x:str="">30L/min</td> </tr> <tr> <td x:str=""><strong>Maximum lift</strong></td> <td x:str="">8m</td> </tr> <tr> <td x:str=""><strong>Noise</strong></td> <td x:str="">≤40dB@0.5m</td> </tr> <tr> <td x:str=""><strong>Communication mode</strong></td> <td x:str="">PWM,LIN</td> </tr> </tbody> </table>
<table style="border-collapse:collapse; width:auto"> <tbody> </tr> <tr> <td><strong>Rated Flow and Head </strong></td> <td>16.7L/min@9m </td> </tr> <tr> <td><strong>Rated Power</strong> </td> <td>90W</td> </tr> <tr> <td><strong>Voltage Range</strong></td> <td>8~16V DC</td> </tr> <tr> <td><strong>Max. head</strong></td> <td>41L/min</td> </tr> <tr> <td><strong>Max. flow</strong></td> <td>9.5m</td> </tr> <tr> <td><strong>Noise</strong></td> <td>≤45dB(A)@ 0.5m </td> </tr> <tr> <td><strong>Communication</strong></td> <td>PWM</td> </tr> </tbody> </table>
<table height="122" style="border-collapse:collapse; width:auto"> <colgroup> <col style="width:207.00pt" width="276" /> <col style="width:163.50pt" width="218" /> </colgroup> <tbody> <tr> <td x:str=""><strong>Rated flow head</strong></td> <td x:str="">30L/min@8m</td> </tr> <tr> <td x:str=""><strong>Power</strong></td> <td x:str="">120W</td> </tr> <tr> <td x:str=""><strong>Voltage range</strong></td> <td x:str="">8 ~ 16VDC</td> </tr> <tr> <td x:str=""><strong>Maximum flow</strong></td> <td x:str="">50.5L/min</td> </tr> <tr> <td x:str=""><strong>Maximum lift</strong></td> <td x:str="">13.3m</td> </tr> <tr> <td x:str=""><strong>Noise</strong></td> <td x:str=""> ≤45dB(A)@0.5m</td> </tr> <tr> <td x:str=""><strong>Communication mode</strong></td> <td x:str="">PWM,LIN</td> </tr> </tbody> </table>
<table height="122" style="border-collapse:collapse; width:auto"> <colgroup> <col style="width:207.00pt" width="276" /> <col style="width:163.50pt" width="218" /> </colgroup> <tbody> <tr> <td x:str=""><strong>Rated flow head</strong></td> <td x:str="">30L/min@13m</td> </tr> <tr> <td x:str=""><strong>Power</strong></td> <td x:str="">160W</td> </tr> <tr> <td x:str=""><strong>Voltage range</strong></td> <td x:str="">16 ~ 32VDC</td> </tr> <tr> <td x:str=""><strong>Maximum flow</strong></td> <td x:str="">60L/min</td> </tr> <tr> <td x:str=""><strong>Maximum lift</strong></td> <td x:str="">13.2m</td> </tr> <tr> <td x:str=""><strong>Noise</strong></td> <td x:str="">≤50dB@0.5m</td> </tr> <tr> <td x:str=""><strong>Communication mode</strong></td> <td x:str="">PWM</td> </tr> </tbody> </table>
<table height="122" style="border-collapse:collapse; width:auto"> <colgroup> <col style="width:207.00pt" width="276" /> <col style="width:163.50pt" width="218" /> </colgroup> <tbody> <tr> <td x:str=""><strong>Rated flow head</strong></td> <td x:str="">26L/min@13m</td> </tr> <tr> <td x:str=""><strong>Power</strong></td> <td x:str="">160W</td> </tr> <tr> <td x:str=""><strong>Voltage range</strong></td> <td x:str="">8 ~ 16VDC</td> </tr> <tr> <td x:str=""><strong>Maximum flow</strong></td> <td x:str="">54L/min</td> </tr> <tr> <td x:str=""><strong>Maximum lift</strong></td> <td x:str="">14.2m</td> </tr> <tr> <td x:str=""><strong>Noise</strong></td> <td x:str=""> ≤45dB@0.5m</td> </tr> <tr> <td x:str=""><strong>Communication mode</strong></td> <td x:str="">LIN,PWM</td> </tr> </tbody> </table>
<table height="122" style="border-collapse:collapse; width:auto"> <colgroup> <col style="width:207.00pt" width="276" /> <col style="width:163.50pt" width="218" /> </colgroup> <tbody> <tr> <td x:str=""><strong>Rated flow and head</strong></td> <td x:str="">165L/min@15.2m</td> </tr> <tr> <td x:str=""><strong>Power</strong></td> <td x:str="">900W</td> </tr> <tr> <td x:str=""><strong>Rated voltage</strong></td> <td x:str="">345V DC</td> </tr> <tr> <td x:str=""><strong>High voltage range</strong></td> <td x:str="">250 to 450V DC</td> </tr> <tr> <td x:str=""><strong>Low voltage range</strong></td> <td x:str="">9 to 32V DC</td> </tr> <tr> <td x:str=""><strong>Maximum flow</strong></td> <td x:str="">210L/min</td> </tr> <tr> <td x:str=""><strong>Maximum head</strong></td> <td x:str="">18.9m</td> </tr> <tr> <td x:str=""><strong>Noise</strong></td> <td x:str="">≤60dB@1m</td> </tr> <tr> <td x:str=""><strong>Communication mode</strong></td> <td x:str="">CAN 2.0B</td> </tr> </tbody> </table>
<br><table align="center" border="1" cellpadding="0" cellspacing="0" style="width:100%;"> <tbody> <tr> <td><strong>Model</strong></td> <td>EPH1500H-00</td> </tr> <tr> <td><strong>Rated Flow and Head</strong></td> <td>210L/min@122m</td> </tr> <tr> <td><strong>Rated Power</strong> </td> <td>1500W</td> </tr> <tr> <td><strong>Rated Voltage </strong></td> <td>545V DC</td> </tr> <tr> <td><strong>Max. head</strong></td> <td>330L/min</td> </tr> <tr> <td><strong>Max. flow</strong></td> <td>27m</td> </tr> <tr> <td><strong>Noise</strong></td> <td>≤65dB(A) @ 1m </td> </tr> <tr> <td><strong>Communication</strong></td> <td>CAN2.0B</td> </tr> </tbody> </table>
<br><table align="center" border="1" cellpadding="0" cellspacing="0" style="width:100%;"> <tbody> <tr> <td><strong>Model</strong></td> <td>EPH900H-00</td> </tr> <tr> <td><strong>Rated Flow and Head</strong></td> <td>165L/min@15.2m</td> </tr> <tr> <td><strong>Rated Power</strong> </td> <td>900W</td> </tr> <tr> <td><strong>Rated Voltage </strong></td> <td>545V DC</td> </tr> <tr> <td><strong>Max. head</strong></td> <td>210L/min</td> </tr> <tr> <td><strong>Max. flow</strong></td> <td>18.9m</td> </tr> <tr> <td><strong>Noise</strong></td> <td>≤60dB(A) @ 1m </td> </tr> <tr> <td><strong>Communication</strong></td> <td>CAN2.0B</td> </tr> </tbody> </table>
<br><table align="center" border="1" cellpadding="0" cellspacing="0" style="width:100%;"> <tbody> <tr> <td><strong>Model</strong></td> <td>EPH2500H-00</td> </tr> <tr> <td><strong>Rated Flow and Head</strong></td> <td>260L/min@24m</td> </tr> <tr> <td><strong>Rated Power</strong> </td> <td>2500W</td> </tr> <tr> <td><strong>Rated Voltage </strong></td> <td>545V DC</td> </tr> <tr> <td><strong>Max. head</strong></td> <td>330L/min</td> </tr> <tr> <td><strong>Max. flow</strong></td> <td>30m</td> </tr> <tr> <td><strong>Noise</strong></td> <td>≤70dB(A) @ 1m </td> </tr> <tr> <td><strong>Communication</strong></td> <td>CAN2.0B</td> </tr> </tbody> </table>
<br><table align="center" border="1" cellpadding="0" cellspacing="0" style="width:100%;"> <tbody> <tr> <td><strong>Model</strong></td> <td>EPH2500H-D4</td> </tr> <tr> <td><strong>Rated Flow and Head</strong></td> <td>360L/min@17m</td> </tr> <tr> <td><strong>Rated Power</strong> </td> <td>2500W</td> </tr> <tr> <td><strong>Rated Voltage </strong></td> <td>545V DC</td> </tr> <tr> <td><strong>Max. head</strong></td> <td>400L/min</td> </tr> <tr> <td><strong>Max. flow</strong></td> <td>30m</td> </tr> <tr> <td><strong>Noise</strong></td> <td>≤70dB(A) @ 1m </td> </tr> <tr> <td><strong>Communication</strong></td> <td>CAN2.0B</td> </tr> </tbody> </table>
Electric vehicle liquid cooling pump
We are committed to providing customers with professional thermal management system solutions for new energy vehicles.
MORE +Hydrogen fuel cell liquid cooling pump
We are committed to providing customers with professional thermal management system solutions for new energy vehicles.
MORE +Cooperative Clients
With your trust and support, we will work harder to serve you and achieve a win-win situation in the coming years!
MORE +Electric vehicle liquid cooling pump
Hydrogen fuel cell liquid cooling pump
Cooperative Clients
06-20
From June 18th to 20th, 2025, the 2025 International Hydrogen and Fuel Cell Vehicle Conference and Exhibition (FCVC2025) will grandly open at the Shanghai Automotive Convention and Exhibition Center. The theme of this exhibition is "Building Consensus, Overcoming Difficulties, and Promoting Industrial Scale Development Together", gathering cutting-edge forces in the global hydrogen and fuel cell industry.
06-06
From June 4th to 6th, 2025, the annual "First Pump and Valve Exhibition" - Shanghai International Pump and Valve Exhibition grandly kicked off at the Shanghai National Convention and Exhibition Center! As the largest pump and valve exhibition in China, Shanghai Pump and Valve Exhibition takes "new quality productivity" as the engine and "industry going global" as the navigation mark, breaking through the waves of global economic and trade changes. Every year, it gathers the latest pump and valve products, technologies, and solutions from around the world, and has developed into the preferred communication platform for global pump and valve professionals.
05-21
In order to further leverage the role of technical backbone in "inheritance, assistance, and leadership" and accelerate the construction of the talent team, on the afternoon of May 20, 2025, the company held the first apprenticeship ceremony with the theme of "Inheriting Craftsmanship, Building the Future Together". General Manager Han Zongxi, department leaders, five pairs of mentors and apprentices, and all employees of the R&D department gathered together to participate in this event.


Address: No.1 Yanglin Road, Baiyan Science and Technology Park, High tech Zone, Hefei City, Anhui Province

zip code:230088


Follow us