The Leader in Liquid Cooling Pump Technology in China
MORE +
scroll down
ABOUT

Hefei Shinhoo New Energy Co.,ltd.

We are committed to providing customers with professional thermal management system solutions for new energy vehicles.

Hefei Shinhoo New Energy Co., Ltd. (Shinhoo), a wholly-owned subsidiary of Zhejiang Dayuan Pump Co., Ltd. (Stock Code: 603757), operates as a technology-driven enterprise specializing in thermal management solutions for the new energy sector. Headquartered in Hefei, China, we excel in the R&D, production, and global distribution of advanced liquid cooling systems.

Learn more →
图片名称
Electric vehicle liquid cooling pump Hydrogen fuel cell liquid cooling pump

<table style="border-collapse:collapse; width:auto"> <colgroup> <col style="width:207.00pt" width="276" /> <col style="width:163.50pt" width="218" /> </colgroup> <tbody> <tr> <td x:str=""><strong>Rated flow head</strong></td> <td x:str="">16L/min@7m</td> </tr> <tr> <td x:str=""><strong>Power</strong></td> <td x:str="">60W</td> </tr> <tr> <td x:str=""><strong>Voltage range</strong></td> <td x:str="">8 ~ 16VDC</td> </tr> <tr> <td x:str=""><strong>Maximum flow</strong></td> <td x:str="">30L/min</td> </tr> <tr> <td x:str=""><strong>Maximum lift</strong></td> <td x:str="">8m</td> </tr> <tr> <td x:str=""><strong>Noise</strong></td> <td x:str="">&le;40dB@0.5m</td> </tr> <tr> <td x:str=""><strong>Communication mode</strong></td> <td x:str="">PWM,LIN</td> </tr> </tbody> </table>

<table style="border-collapse:collapse; width:auto"> <tbody> </tr> <tr> <td><strong>Rated Flow and Head&nbsp; &nbsp;&nbsp;</strong></td> <td>16.7L/min@9m&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;</td> </tr> <tr> <td><strong>Rated Power</strong>&nbsp;</td> <td>90W</td> </tr> <tr> <td><strong>Voltage Range</strong></td> <td>8~16V DC</td> </tr> <tr> <td><strong>Max. head</strong></td> <td>41L/min</td> </tr> <tr> <td><strong>Max. flow</strong></td> <td>9.5m</td> </tr> <tr> <td><strong>Noise</strong></td> <td>&le;45dB(A)@ 0.5m&nbsp;</td> </tr> <tr> <td><strong>Communication</strong></td> <td>PWM</td> </tr> </tbody> </table>

<table height="122" style="border-collapse:collapse; width:auto"> <colgroup> <col style="width:207.00pt" width="276" /> <col style="width:163.50pt" width="218" /> </colgroup> <tbody> <tr> <td x:str=""><strong>Rated flow head</strong></td> <td x:str="">30L/min@8m</td> </tr> <tr> <td x:str=""><strong>Power</strong></td> <td x:str="">120W</td> </tr> <tr> <td x:str=""><strong>Voltage range</strong></td> <td x:str="">8 ~ 16VDC</td> </tr> <tr> <td x:str=""><strong>Maximum flow</strong></td> <td x:str="">50.5L/min</td> </tr> <tr> <td x:str=""><strong>Maximum lift</strong></td> <td x:str="">13.3m</td> </tr> <tr> <td x:str=""><strong>Noise</strong></td> <td x:str="">&nbsp;&le;45dB(A)@0.5m</td> </tr> <tr> <td x:str=""><strong>Communication mode</strong></td> <td x:str="">PWM,LIN</td> </tr> </tbody> </table>

<table height="122" style="border-collapse:collapse; width:auto"> <colgroup> <col style="width:207.00pt" width="276" /> <col style="width:163.50pt" width="218" /> </colgroup> <tbody> <tr> <td x:str=""><strong>Rated flow head</strong></td> <td x:str="">30L/min@13m</td> </tr> <tr> <td x:str=""><strong>Power</strong></td> <td x:str="">160W</td> </tr> <tr> <td x:str=""><strong>Voltage range</strong></td> <td x:str="">16 ~ 32VDC</td> </tr> <tr> <td x:str=""><strong>Maximum flow</strong></td> <td x:str="">60L/min</td> </tr> <tr> <td x:str=""><strong>Maximum lift</strong></td> <td x:str="">13.2m</td> </tr> <tr> <td x:str=""><strong>Noise</strong></td> <td x:str="">&le;50dB@0.5m</td> </tr> <tr> <td x:str=""><strong>Communication mode</strong></td> <td x:str="">PWM</td> </tr> </tbody> </table>

<table height="122" style="border-collapse:collapse; width:auto"> <colgroup> <col style="width:207.00pt" width="276" /> <col style="width:163.50pt" width="218" /> </colgroup> <tbody> <tr> <td x:str=""><strong>Rated flow head</strong></td> <td x:str="">26L/min@13m</td> </tr> <tr> <td x:str=""><strong>Power</strong></td> <td x:str="">160W</td> </tr> <tr> <td x:str=""><strong>Voltage range</strong></td> <td x:str="">8 ~ 16VDC</td> </tr> <tr> <td x:str=""><strong>Maximum flow</strong></td> <td x:str="">54L/min</td> </tr> <tr> <td x:str=""><strong>Maximum lift</strong></td> <td x:str="">14.2m</td> </tr> <tr> <td x:str=""><strong>Noise</strong></td> <td x:str="">&nbsp;&le;45dB@0.5m</td> </tr> <tr> <td x:str=""><strong>Communication mode</strong></td> <td x:str="">LIN,PWM</td> </tr> </tbody> </table>

<table height="122" style="border-collapse:collapse; width:auto"> <colgroup> <col style="width:207.00pt" width="276" /> <col style="width:163.50pt" width="218" /> </colgroup> <tbody> <tr> <td x:str=""><strong>Rated flow and head</strong></td> <td x:str="">165L/min@15.2m</td> </tr> <tr> <td x:str=""><strong>Power</strong></td> <td x:str="">900W</td> </tr> <tr> <td x:str=""><strong>Rated voltage</strong></td> <td x:str="">345V DC</td> </tr> <tr> <td x:str=""><strong>High voltage range</strong></td> <td x:str="">250 to 450V DC</td> </tr> <tr> <td x:str=""><strong>Low voltage range</strong></td> <td x:str="">9 to 32V DC</td> </tr> <tr> <td x:str=""><strong>Maximum flow</strong></td> <td x:str="">210L/min</td> </tr> <tr> <td x:str=""><strong>Maximum head</strong></td> <td x:str="">18.9m</td> </tr> <tr> <td x:str=""><strong>Noise</strong></td> <td x:str="">&le;60dB@1m</td> </tr> <tr> <td x:str=""><strong>Communication mode</strong></td> <td x:str="">CAN 2.0B</td> </tr> </tbody> </table>

<br><table align="center" border="1" cellpadding="0" cellspacing="0" style="width:100%;"> <tbody> <tr> <td><strong>Model</strong></td> <td>EPH1500H-00</td> </tr> <tr> <td><strong>Rated Flow and Head</strong></td> <td>210L/min@122m</td> </tr> <tr> <td><strong>Rated Power</strong>&nbsp;</td> <td>1500W</td> </tr> <tr> <td><strong>Rated Voltage&nbsp;</strong></td> <td>545V DC</td> </tr> <tr> <td><strong>Max. head</strong></td> <td>330L/min</td> </tr> <tr> <td><strong>Max. flow</strong></td> <td>27m</td> </tr> <tr> <td><strong>Noise</strong></td> <td>&le;65dB(A) @ 1m&nbsp;</td> </tr> <tr> <td><strong>Communication</strong></td> <td>CAN2.0B</td> </tr> </tbody> </table>

<br><table align="center" border="1" cellpadding="0" cellspacing="0" style="width:100%;"> <tbody> <tr> <td><strong>Model</strong></td> <td>EPH900H-00</td> </tr> <tr> <td><strong>Rated Flow and Head</strong></td> <td>165L/min@15.2m</td> </tr> <tr> <td><strong>Rated Power</strong>&nbsp;</td> <td>900W</td> </tr> <tr> <td><strong>Rated Voltage&nbsp;</strong></td> <td>545V DC</td> </tr> <tr> <td><strong>Max. head</strong></td> <td>210L/min</td> </tr> <tr> <td><strong>Max. flow</strong></td> <td>18.9m</td> </tr> <tr> <td><strong>Noise</strong></td> <td>&le;60dB(A) @ 1m&nbsp;</td> </tr> <tr> <td><strong>Communication</strong></td> <td>CAN2.0B</td> </tr> </tbody> </table>

<br><table align="center" border="1" cellpadding="0" cellspacing="0" style="width:100%;"> <tbody> <tr> <td><strong>Model</strong></td> <td>EPH2500H-00</td> </tr> <tr> <td><strong>Rated Flow and Head</strong></td> <td>260L/min@24m</td> </tr> <tr> <td><strong>Rated Power</strong>&nbsp;</td> <td>2500W</td> </tr> <tr> <td><strong>Rated Voltage&nbsp;</strong></td> <td>545V DC</td> </tr> <tr> <td><strong>Max. head</strong></td> <td>330L/min</td> </tr> <tr> <td><strong>Max. flow</strong></td> <td>30m</td> </tr> <tr> <td><strong>Noise</strong></td> <td>&le;70dB(A) @ 1m&nbsp;</td> </tr> <tr> <td><strong>Communication</strong></td> <td>CAN2.0B</td> </tr> </tbody> </table>

<br><table align="center" border="1" cellpadding="0" cellspacing="0" style="width:100%;"> <tbody> <tr> <td><strong>Model</strong></td> <td>EPH2500H-D4</td> </tr> <tr> <td><strong>Rated Flow and Head</strong></td> <td>360L/min@17m</td> </tr> <tr> <td><strong>Rated Power</strong>&nbsp;</td> <td>2500W</td> </tr> <tr> <td><strong>Rated Voltage&nbsp;</strong></td> <td>545V DC</td> </tr> <tr> <td><strong>Max. head</strong></td> <td>400L/min</td> </tr> <tr> <td><strong>Max. flow</strong></td> <td>30m</td> </tr> <tr> <td><strong>Noise</strong></td> <td>&le;70dB(A) @ 1m&nbsp;</td> </tr> <tr> <td><strong>Communication</strong></td> <td>CAN2.0B</td> </tr> </tbody> </table>

Electric vehicle liquid cooling pump

We are committed to providing customers with professional thermal management system solutions for new energy vehicles.

MORE +

Hydrogen fuel cell liquid cooling pump

We are committed to providing customers with professional thermal management system solutions for new energy vehicles.

MORE +

Cooperative Clients

With your trust and support, we will work harder to serve you and achieve a win-win situation in the coming years!

MORE +

Electric vehicle liquid cooling pump

Hydrogen fuel cell liquid cooling pump

Cooperative Clients

06-20

Shinhoo New Energy makes a brilliant debut at FCVC2025, jointly promoting the large-scale development of the hydrogen energy industry

From June 18th to 20th, 2025, the 2025 International Hydrogen and Fuel Cell Vehicle Conference and Exhibition (FCVC2025) will grandly open at the Shanghai Automotive Convention and Exhibition Center. The theme of this exhibition is "Building Consensus, Overcoming Difficulties, and Promoting Industrial Scale Development Together", gathering cutting-edge forces in the global hydrogen and fuel cell industry.

06-06

Innovation drives the future | Shinhoo New Energy showcases its new products at the 2025 Shanghai International Pump and Valve Exhibition

From June 4th to 6th, 2025, the annual "First Pump and Valve Exhibition" - Shanghai International Pump and Valve Exhibition grandly kicked off at the Shanghai National Convention and Exhibition Center! As the largest pump and valve exhibition in China, Shanghai Pump and Valve Exhibition takes "new quality productivity" as the engine and "industry going global" as the navigation mark, breaking through the waves of global economic and trade changes. Every year, it gathers the latest pump and valve products, technologies, and solutions from around the world, and has developed into the preferred communication platform for global pump and valve professionals.

05-21

Inheriting craftsmanship, building the future together | The first apprenticeship ceremony of Shinhoo New Energy 2025 begins with warmth.

In order to further leverage the role of technical backbone in "inheritance, assistance, and leadership" and accelerate the construction of the talent team, on the afternoon of May 20, 2025, the company held the first apprenticeship ceremony with the theme of "Inheriting Craftsmanship, Building the Future Together". General Manager Han Zongxi, department leaders, five pairs of mentors and apprentices, and all employees of the R&D department gathered together to participate in this event.